As long as there are no sharp edges in the chase that might physically damage the cable, there’s no code violation if Romex touches metal hvac supply or return ducts. … Metal chimneys and other combustion vents are a different matter, however, since they have necessary clearances that must be maintained.
similarly, Can a dryer vent hose be too short?
No. You must have a back draft damper (you can find these at any home center) at the end of the exhaust. You would then attach your dryer venting apparatus to the damper assembly. If you where planning on running flexible duct through the wall that is also a code violation.
on the other hand, Can dryer vent touching gas line?
You shouldn’t have any problems, dryer vents don’t get hot enough to hurt the gas line. I’d agree. If you’re that worried about it though you could put some insulation on the gas line.
also, Can dryer vent touching PVC? While PVC is meant for plumbing and venting applications, PVC is not approved for venting a clothes dryer and should not be used for this application. PVC pipe can allow a static charge to build up; this static charge can ignite the dryer lint leading to a fire.
Can PEX touch dryer vent?
2) Dryer installation instructions typically prohibit contact with combustible materials. So PEX less than 6“ from a dryer exhaust falls in a gray area somewhere between these requirements.
What type of dryer vent hose is best?
Venting Guidelines
- All dryer ducting must be a minimum of 4″ in diameter. …
- Flexible transition hose between the dryer and the wall outlet should be either the foil type or the aluminum flexible duct (most preferred). …
- Concealed ducting must be rigid metal (galvanized or aluminum) duct.
Is flexible dryer vent safe?
Foil flexible ducts are pliable and easy to install. … White vinyl spiral ducts are still found in many homes, but are not UL approved for clothes dryer transition ducts. They’re very unsafe, burn more easily than foil ducts, and are prohibited by most building codes and appliance manufacturers.
Can I use PVC for a dryer vent?
PVC pipe is fantastic for many different applications, and it is even sometimes used for duct and venting applications, but there are a few reasons why PVC pipe is not a great choice for dryer vents. … All PVC pipe and fittings have a max operating temp of 140 degrees Fahrenheit.
How close can gas line be to dryer vent?
The following are clearances from the gas regulator vent that should be followed: A building air intake system either gravity or power must be 10 feet away from a gas vent; the clothes dryer must vent at least 3 feet away from the gas vent, and an appliance exhaust and any appliance air intake should be a minimum of 3 …
Can I use ABS pipe for dryer vent?
1 Answer. Residential clothes dryers typically vent at a temperature of around 130°-165°F (54°-74°C). Wikipedia gives the glass transition temperature (colloquially the melting point) of ABS as 221°F (105°C). Even assuming that you get a perfect heat transfer, you’ll be fine.
Can a dryer duct touch wood?
Yes, that is considered safe. Direct wood contact is not a problem with the operating temperature of a dryer vent. You’ll have no fire if the vent is clear. lint does not escape from the pipe if all joints are foil taped.
Is flexible dryer duct safe?
Foil flexible ducts are pliable and easy to install. … White vinyl spiral ducts are still found in many homes, but are not UL approved for clothes dryer transition ducts. They’re very unsafe, burn more easily than foil ducts, and are prohibited by most building codes and appliance manufacturers.
Can you run hot and cold PEX side by side?
Hot and cold PEX water lines run through the same hole in a stud wall. … This is not a typical installation; both pipes should have their own holes to pass through the framing.
How often should you change your dryer vent hose?
According to The Consumer Product Safety Commission, ( CPSC ), annually there are tens of thousands of Dryer Fires leading to many injuries or death, due to dryer exhaust duct fires. You should clean your dryer hose and around it once a year, and inspect the vent and hose for any blockages at least every 6 months.
Can I use dryer without vent hose?
The answer to the question, “Can I safely run my dryer without a vent?” is simply, No. You cannot safely run a dryer without a vent. … To operate correctly, dryers need vents that allow heat, lint, and moisture to be expelled outdoors.
Does Walmart sell dryer vent hose?
Foil Dryer Vent Hose Kit with Metal Clamps 4″ x 5′ – Walmart.com – Walmart.com.
How often should you replace your dryer vent hose?
According to The Consumer Product Safety Commission, ( CPSC ), annually there are tens of thousands of Dryer Fires leading to many injuries or death, due to dryer exhaust duct fires. You should clean your dryer hose and around it once a year, and inspect the vent and hose for any blockages at least every 6 months.
Can you cut flexible dryer vent hose?
Can you cut flexible dryer vent hose? Trim the hose. Using your tin snips (believe us, scissors won’t cut it here), carefully trim the vent hose along the line you marked off with tape. And don’t forget your gloves – the thin metal hose often has really sharp edges once it’s cut.
Should dryer vent have a screen?
Though exceedingly common, for reasons we’ll explore later, it is against International Regulation Code, and generally an unsafe practice, to place or keep any kind of screen over a dryer exhaust vent. … Exhaust ducts shall terminate on the outside of the building.
Is it safe to vent dryer into garage?
If you have a gas-fired dryer, it’s not only a bad idea to vent it into your garage, it’s potentially deadly. Gas-fired dryers eject small amounts of carbon monoxide, and it’s critical that they’re properly vented to the outdoors. … Dryer vents should be as straight as possible and not exceed 35 feet in length.
What can you use for dryer vent pipe?
Here are the most common dryer duct materials used to install a dryer vent.
- 01 of 05. Aluminum Foil Duct. Image by Marie LaFauci / Getty Images. …
- 02 of 05. Semi-Rigid Metal Duct. Kameleon007 / Getty Images. …
- 03 of 05. Slim Duct. …
- 04 of 05. Rigid Metal Duct. …
- 05 of 05. Plastic or Vinyl Duct.
How much clearance does a dryer vent need?
The minimum clearance distance from the bottom of a clothes dryer vent terminating hood to the surface of the ground or to the surface of any other obstruction is 12″.
Is a dryer vent considered a source of ignition?
A dryer vent is not an ignition source. An open flame, or something that is creating a spark regularly is an ignition source. They don’t get extremely hot.
Can 2 dryers share the same vent?
The ductwork for both dryers should be kept completely separate. The 4-inch diameter of standard clothes dryers is designed to handle the flow of air for one appliance only. It’s fine to run the ducts parallel.