– Enter programming. …
– Enter the appropriate section for the zone(s) you’re programming. …
– Once in that programming section each zone, in order, will have a 2-digit zone definition.
Thereof, How do I disable a zone on my DSC alarm?
– The System Must be disarmed prior to proceeding.
– Press the * Key.
– Press the 1 Key.
– Use the > key to scroll to the zone you wish to bypass.
– Press the * Key on the appropriate zone.
– A “B” should appear next to the zone when the system is bypassed.
Also to know is, How do you program a DSC keypad?
Subsequently, question is, What is the ADT installer code? You can always try the default Installer Code first but it would be unusual for a security dealer to not change the code as part of their installation procedure. If you have an ADT SafeWatch which is a rebranded Honeywell Vista control, the default Installer Code is 6321.
Also, How do I find my master code for DSC alarm?
What is an installer code?
The Installer Code on a panel is used for entering installer programming mode. In this mode, various changes to the function of the system can be made. Meanwhile, the Master Code is used primarily for arming and disarming.
How do you delete a zone on a DSC alarm?
– Enter wireless programming. Start from the main screen of your push-button keypad. …
– Access delete zone menu. On your keypad, enter [901]. …
– Delete the zone. …
– Return to main screen.
How do I deactivate my alarm system?
You can turn off or power down your home alarm system by disconnecting its backup battery and then unplugging the transformer for the device from the wall outlet. You can confirm that the panel has been powered down by checking its touchscreen or keypad and making sure that it is blank.
How do I permanently bypass a zone on a DSC alarm?
– The System Must be disarmed prior to proceeding.
– Press the * Key.
– Press the 1 Key.
– Use the > key to scroll to the zone you wish to bypass.
– Press the * Key on the appropriate zone.
– A “B” should appear next to the zone when the system is bypassed.
How do I factory reset my DSC 1832?
Time to factory reset the system. To do this you have to short the zone 1 pin (not the z1 common pin) with the PGM1 pin. Thus, you have to ground Z1 to PGM and power the system up for 10 seconds and then power it off, remove the jumper and then power it back on.
How do you clear a DSC alarm trouble code?
DSC alarms can go off for a number of reasons. To reset the alarm or the warning lights, enter your master code twice, press the reset button, and then enter “*72” if the alarm is still ringing.
Where do I find my ADT master code?
Find the System tab and then click on the name of your security system. Click on the Change button and then you will see the Security Panel Access Code window. In the New Master Code field, type in the code you want to create and then re-type it in the box below. You will then see a Password box.
How do I set a default DSC alarm?
– Prepare the terminals. If there are any wires connected to the Z1 and PGM1 terminals, remove them and mark them appropriately. …
– Power panel down. …
– Short across terminals. …
– Apply AC power. …
– Remove AC power. …
– Remove the jumper. …
– Restore power.
What is a PGM output?
So a PGM is a programmable negative trigger output. What does this mean? You can think of a PGM as an on/off switch like a light switch. It will be connected to something to provide power that can be turned on or off. The system will flip the switch based on what PGM type you program it for.
How do I program DSC wireless contacts?
– Enter section 898. …
– You will now trip the first wireless device that you want to add. …
– Check that the ESN on the device and the keypad match and then press *.
– You will now need to enter a zone number.
– Then the system will ask for a zone type.
How do you clear the memory on a DSC alarm system?
To clear the memory, arm and disarm the system. Certain sensors (such as smoke detectors and glass break detectors) have to be reset after an alarm. To reset detectors, press and hold the RESET key () for 2 seconds. If a sensor fails to reset, it may still be detecting an alarm condition.
How do you bypass an alarm zone?
– Enter the following: Your 4-digit code. The number 6 (bypass button) Two-digit zone number of the zone you want to bypass. (01, 02, 03, etc.)
– Repeat this process for all zones you would like to bypass.
– Once your system is disarmed, this process will need to be repeated in order to arm your system again.